What do Rinnai tankless error codes mean? Full code table

Last reviewed Expert review pending 5 min read 3 sources

Short answer

Rinnai codes point to a system: 10 is blocked venting, 11 is no ignition, 12 is flame loss, 14 is overheat, 25 is a condensate backup, and LC or SS means a flush is due. Owners can check gas, power, water valves, the inlet filter, vent terminals and the condensate line. Sensor, fan, valve and board codes need a pro.

Key facts

  • Rinnai code 11 means the burner did not light; the first checks are the gas valve, gas service, and propane level.[1]
  • Rinnai says to treat code 14, the overheat protection, seriously rather than repeatedly resetting it.[1]
  • LC is the only Rinnai code that lets the unit keep running; it warns of scale building up in the heat exchanger.[1]

Before you use this table

If you smell gas, do not reset anything. Leave on foot, avoid anything that can spark, and call the gas utility and 911 from a safe place[2].

The table below paraphrases Rinnai's diagnostic code guide in our own words[1]. It is not Rinnai's text. Rinnai splits its line into SENSEI condensing models (RX, CX, RE, RSC, sold since 2019), non-SENSEI models (V-series, RL, RU, RUR, RUC and commercial C-series), and the RH180 hybrid. The "Applies to" notes tell you which. Meanings marked with an asterisk (*) are inferred from the checks Rinnai lists for that code; confirm them in your model's manual.

"Power cycle once" means turning the unit off and back on one time. If the code returns, stop.

Rinnai code table

CodeWhat it meansSafe homeowner checkCall a pro when
02*Freeze protection ran but the burner could not fire (non-SENSEI)Gas valve to the heater open; gas service onCode returns with gas confirmed on
03*Power was lost mid-cycle, such as during a bath fillClose hot taps, press On/Off twice, retryIt keeps coming back (possible board fault)
05Bypass flow control valve faultPower cycle onceIt returns: the valve needs testing or replacement
07*RH180 only: low water supply pressure, pump not running, or clogged filterCold supply valve open; clean the inlet filterPump or heat exchanger service is needed
10Combustion air or exhaust blocked, or a full condensate trap (condensing)Clear snow, leaves or nests from the outside vent; check the condensate line drainsIt returns: vent system or heat exchanger needs inspection
11No ignition: burner did not lightGas valve open at the heater and meter; propane tank not empty; power cycle onceStill no light: gas pressure, igniter or flame rod check
12Flame lit, then went outConfirm gas supply; note if it fails when other gas appliances runAny repeat: gas pressure test under load, flame rod, venting
13*Poor combustion on B-vent (atmospheric) modelsNote whether opening the door to the room helps, and tell the proAlways: venting or combustion air needs correcting
14Overheat protection tripped. Rinnai says to take this one seriouslyShut the unit off; do not keep resettingAlways
15*SENSEI: gas valve or venturi control faultPower cycle once; check vent terminals are clearIt returns
16Outlet water hotter than expectedCheck the vent terminal and the space around the unit for obstructionsIt returns, especially with a recirculation system
17*SENSEI: venturi or vent blockage; unit locks outCheck the condensate line and vent terminalsAlways: the venturi must be cleaned and the lockout reset
19*Electrical grounding or current leakage faultPower cycle onlyAlways: electrical diagnosis
21*SENSEI: board data transfer fault, usually after a board replacementNoneAlways: the board needs reprogramming
25Condensate backup (condensing models)Check the condensate line for kinks, clogs or iceTrap or neutralizer service is needed
30 or FERH180: flammable vapor sensor trippedLeave the area until it is safe; then remove gasoline, paint or solvents from the roomSensor testing, or if you smell gas
31*RH180: burner manifold gas pressure setting problemNoneAlways: gas pressure adjustment
32, 33, 34, 35, 38, 41, 51*A temperature sensor reads out of range: outlet water (32), heat exchanger outlet (33), combustion air (34), RH180 tank (35), exhaust (38), outdoor or freeze protection (41), inlet water (51)Power cycle onlyAlways: sensor test and replacement
52Modulating gas valve signal faultNoneAlways
54Exhaust temperature too high (Rinnai cites about 163 F)Check the vent terminalHeat exchanger service or vent repair is needed
57, 58Non-SENSEI condensing (KB): a safety switch opened on the burner (57) or secondary heat exchanger (58)NoneAlways: usually overheating or blockage
61Combustion fan faultNoneAlways: fan or wiring
63*Recirculation problem: pump, settings, or air in the loopNoneAlways: recirculation setup or pump service
65Water flow control (servo) valve faultNoneAlways
70, 71, 72, 73*Internal control faults: board parameters (70), gas solenoid circuit (71), flame sensing (72), burner sensor (73, non-SENSEI)Power cycle onceAlways if it returns
79Internal water leak detected (non-SENSEI)Shut off water and power to the unit; put a pan under itAlways
FFNot a fault: a marker that maintenance was doneNo actionn/a
SESENSEI commercial cascade messageNoneCascade wiring or setup issue
SSSENSEI: service reminder; a heat exchanger flush is dueSchedule a flush; the owner's manual gives the reset stepsYou prefer not to flush it yourself
LC (LC0 to LC9)Scale building up in the heat exchanger (non-SENSEI). The unit keeps runningSchedule a flush; consider water treatmentBefore it progresses to a shutdown code

Source: Rinnai document 100000652[1], paraphrased.

The codes owners see most

10, 11 and 12 account for many no-hot-water calls, and all three start with things you can check: the outside vent, the gas valve and the gas supply. If you are on propane, check the tank first.

14 is the one not to fight. An overheat trip means something let the unit get too hot. Shut it off and call.

LC and SS are maintenance prompts. Ignoring them lets scale build until it causes overheat or flow faults, which are more expensive. A flush and descale typically runs $75 to $300, per HomeGuide's 2025 figures[3].

When to call a pro

  • Code 14, or any code tied to a sensor, gas valve, fan or board.
  • Codes 10, 11 or 12 that return after the checks above.
  • Code 79, or any water visible inside or under the cabinet.
  • An RH180 flammable vapor code (30 or FE) if the cause is not obvious.

More questions

What is the difference between SENSEI and non-SENSEI Rinnai models?

SENSEI is Rinnai's condensing platform launched in 2019 (RX, CX, RE and RSC models). Non-SENSEI covers the V-series, RL, the RU, RUR and RUC condensing models, and commercial C-series. A few codes exist on only one family.

Can I clear an LC code myself?

The owner's manual describes the flush and the button sequence that clears the reminder. If you are not comfortable isolating the service valves and running descaler through the unit, a plumber typically charges $75 to $300 for a flush.

Sources